HM/DMMI/UL

อุปกรณ์โมดูลตรวจสอบแบบสองสาย สำหรับสัญญาณเตือนอัคคีภัยแบบสัมผัส Honeywell Morley

The HM-DMMI-UL Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally open, contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator.

HM-DMMI-UL Applications: Monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally open, drycontact alarm activation devices. Use it to monitor normally-open supervisory devices with special supervisory indication at the control panel. The monitored circuit may be wired as an NFPA (Class B) Initiating Device Circuit. A 47K Ohm end of line resistor (provided) terminates the Class B circuit.

HM-DMMI-UL Operation: Each HM-DMMI-UL uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of
its Initiating Device Circuit (IDC). A flashing LED indicates that the module communicates with the control panel. The LED steadily illuminates when an alarm starts (subject to current loop limitations).

  • Built-in type identification automatically identifies this device as a monitor module to the control panel
  • Powered directly by two-wire SLC loop. No additional power required
  • High noise (EMF/RFI) immunity
  • SEMS screws with clamping plates for easy wiring
  • Direct-dial entry of address: 61-99 for models SMX and STX
  • LED flashes during normal operation and steadily illuminates to indicate alarm

HM-DMMI-UL TECHNICAL SPECIFICATIONS

Nominal Operating Voltage15 to 32 VDC
Maximum SLC current draw5.0 mA (LED on)
Maximum IDC wiring resistance375 μA (LED flashing), 1 communication every 5 seconds, 47k EOL
Maximum IDC wiring resistance1500 Ohms
Maximum IDC Voltage11 V
EOL resistance47K Ohms
Temperature range32°F to 120°F (0°C to 49°C)
Humidity range10% to 93% non-condensing
Dimensions4.5″ (11.43 cm) high x 4″ (10.16 cm) wide x 1.25″ (3.175 cm) deep. Mounts to a 4″ (10.16 cm) square x 2.125″ (5.398 cm) deep boxS
SYS/HS

Standard: UL

  • It is possible to set the display light to high or low, the volume setting for 3 levels of continuous and temporary.
  • Luxurious design with high aesthetics, compact and easy to install.
  • Automatically synchronize alarm flash light for 30 minutes.
  • Flash mode after 1 second

FEATURES

  • Operating temperature: 0-49 degrees Celsius
  • Humidity: 10-93% RH, No dew condensation.
  • Operating voltage: 16-33 VDC (normally at 24V)
  • Sound intensity: ≥82dBA.
SYS/ST

Horn-Strobe Light Red

Honeywell’s SYS/ST strobe features a red housing and universal fire symbol to meet virtually any application requirement. A mounting plate allows the device to be compatible with a wide range of backbox sizes. Its settings are done using easy-to-set rotary switches on the back of the device while synchronization is achieved without the use of additional modules. When powered with a filtered DC source, it is capable of self synchronization for 30 minutes per NFPA72.

HM/MM3E/UL

HM-MM3E-UL is a miniature monitor module – 1.3” (3.302 cm) H x 2.75” (6.985 cm) W x 0.65” (1.651 cm)
D – that supervises Class B circuit of dry-contact input devices. Thanks to its compact design, the HM-MM3E-UL can be mounted in a single-gang box behind the device it monitors.

HM-MM3E-UL Operation: Each HM-MM3E-UL uses one of the available module addresses on an SLC loop. It responds to regular polls
from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC).

  • Powered directly by two-wire SLC loop No additional power required
  • High noise (EMF/RFI) immunity
  • Tinned, stripped leads for easy wiring
  • Direct-dial entry of address: 61-99 for models SMX and STX

315-508

Honeywell Bluetooth USB Dongle is an elegant Bluetooth Low Energy (BLE) product that is used for seamlessly interfacing with the Morley STX and SMX fire panel models.

The Honeywell Bluetooth Dongle (HONBLEKIT2) is a plug and play module that enables wireless
communication between the panel and the Honeywell SmartConfig™ mobile application for simple, smart and secure commissioning and maintenance operations.


The HONBLEKIT2 is compatible with SmartConfig version 2.0.0.0 onwards.

Following are the features of Honeywell wireless commissioning:

  • Provides seamless wireless low power Bluetooth Connectivity to Morley STX and SMX fire panel models
  • Eases the panel commissioning and maintenance operations through Honeywell SmartConfig™ Mobile app
  • Enables productivity through a simple interface
  • Eliminates the need to carry laptops, cables and so on to the site for configuration

HM/MCP/GLASS/UL

The HM-MCP-GLASS-ULis an addressable manual break glass call point which, as a simple rotary decade, switch at the rear of the unit for addressing.

A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch – enabling a complete functionality test.

The HM-MCP-GLASS- UL call point is designed to provide a manual alarm interface to Morley IAS’s fire alarm control panel.

Installation efficiency and compliance with the latest standards are at the heart of the call point range.

  • Innovative “Plug and Play” installation concept
  • Analogue addressable communications
  • Integral LED

HM/DISO/UL

The HM-DISO-UL Fault Isolator Module is used with the fire alarm control panels (FACPs) to protect the system against wire-to-wire short circuits on the SLC loop. The HM-DISO-UL should be placed between each
device on the SLC loop to isolate a short circuit problem between the modules. It is required for true Style 7 operation, so that other devices can continue to operate normally in the event of a short circuit on the SLC.

  • Powered by SLC loop directly, no external power required
  • Mounts in standard junction boxes (4.0”/10.16 cm square, 2.125”/5.398 cm deep)
  • Integral LED blinks to indicate normal condition and illuminates steady when short circuit condition is detected
  • High noise (EMF/RFI) immunity

HM/DCZRM/UL

HM-DCZRM-UL is a standard-sized module used to monitor and supervise compatible two-wire,
24-Volt, smoke on a Class B circuit.

The HM-DCZRM-UL Interface Module is intended for use in intelligent, addressable systems, where the
individual address of each module is selected using built-in rotary switches. This module allows intelligent
panels to interface and monitor two-wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module.

  • Supports compatible two-wire smoke detectors
  • Supervises IDC wiring and connection of external power source
  • High noise (EMF/RFI) immunity
  • SEMS screws with clamping plates for ease of wiring
  • Direct-dial entry of address: 61 -99 for models SMX and STX
  • LED flashes during normal operation
  • LED steadily illuminates to indicate an alarm on command from the control panel

HM/D240CMO/UL

The HM-D240CMO-UL Addressable Relay Module provides the system with a dry contact output for activating a variety of auxilary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis.

  • Built-in type identification automatically identifies these devices to the control panel
  • Internal circuitry and relay powered directly by two-wire SLC loop
  • Integral LED “blinks” green each time a communication is received from the control panel and turns
    on in steady red when activated
  • High noise immunity (EMF/RFI)
  • Wide viewing angle of LED
  • SEMS screws with clamping plates for wiring ease
  • Direct-dial entry of address: 61 -99 for models SMX and STX

HM/DCMO/UL

The HM-DCMO-UL Addressable Control Module provides a circuit for Notification appliances like horns, strobes, and more. Addressability allows the HM-DCMO-UL to be activated through panel programming, on a select (zone or area of coverage) basis.

  • Built-in type identification automatically matches devices to the control panel
  • Internal circuitry powered directly by a two-wire SLC loop The HM-DCMO-UL module requires power (for horns, strobes, etc.)
  • Integral green LED blinks each time a communication is received from the control panel and turns on steady red when activated
  • High noise immunity (EMF/RFI)
  • The HM-DCMO-UL may be used to switch 24-volt NAC power
  • Wide viewing angle of LED
  • SEMS screws with clamping plates for easy wiring
  • Direct-dial entry of address: 61 -99 for models SMX and STX