Search for:
X-SPT900
X-SPT900

X-SMART Med to Small Project System Management Software Package (Include 1 sever and 1 client interface)

X-SPT900

X-SMART X-618 Management Software

The X-SMART System Management Software includes a server-side system resource platform and a client-side management system to perform centralized management of related devices through an Ethernet network. The software is used to monitor the system status, make announcements, play audio, and manage logs.

There are two kinds of X-SMART software to meet the different requirements of projects of different sizes. One is for small and mediumsized project, and the other is for larger projects. These two kinds of software have the same operations. However, the number of X-DCS3000 (DSC) they control and the size of the devices connected are different

The small and mediumsized project software can manage 20 DCSs at most, and play audio using 20 channels maximum through the network, among which 5 channels are for fire alarms and 15 for normal
announcements.

The large project software can manage up to 250 DCSs and play audio using 60 channels through the network, among which 10 channels are for fire alarms and 50 for public address.

FEATURES

  • Flexible management of operation authorizations
  • Provide multiple-layer map view for the buildings
  • Records and show all events logs
  • Support system data backup
  • Fault detection reports the device ID, Type, and IP address
  • Monitor the status of all devices in the X-618 network
  • Supports multiple simultaneous announcements

X-ST2000
X-ST2000

X-SMART Client Interface

SX-ST2000

X-SMART X-618 Management Software

The X-SMART System Management Software includes a server-side system resource platform and a client-side management system to perform centralized management of related devices through an Ethernet network. The software is used to monitor the system status, make announcements, play audio, and manage logs.

There are two kinds of X-SMART software to meet the different requirements of projects of different sizes. One is for small and mediumsized project, and the other is for larger projects. These two kinds of software have the same operations. However, the number of X-DCS3000 (DSC) they control and the size of the devices connected are different.

The small and mediumsized project software can manage 20 DCSs at most, and play audio using 20 channels maximum through the network, among which 5 channels are for fire alarms and 15 for normal announcements.

The large project software can manage up to 250 DCSs and play audio using 60 channels through the network, among which 10 channels are for fire alarms and 50 for public address.

FEATURES

  • Flexible management of operation authorizations
  • Provide multiple-layer map view for the buildings
  • Records and show all events logs
  • Support system data backup
  • Fault detection reports the device ID, Type, and IP address
  • Monitor the status of all devices in the X-618 network
  • Supports multiple simultaneous announcements

EVACLITE

8 ZONE VOICE ALARM CONTROLLER

EVACLITE

Here’s a cost-effective Voice Alarm system that’s perfect for public places with a requirement of less than 8 loudspeaker circuits (zones). In the event of an emergency, the Evaclite can broadcast evacuation or alert messages to all zones through its built-in loudspeaker. It can also receive information from fire alarm panels and play automated/pre-recorded EVAC/ALERT messages to ensure the safe evacuation of people.
The Evaclite PKG comes with a rich suite of features that enhance its functionalities, such as digital signal processor, special monitoring volume control, built-in USB and local control panel.

FEATURES

  • 775 mV Line Output
  • AC 220V ± 10% 50 / 50 Hz Power Supply Voltage
  • 5A Power Output Capability
  • 20W Rated Power
  • 20 Hz 〜 20 KHz Frequency Response
  • 10.6Kg Gross Weight

X-NPMI
X-NPMI

PMI Configurable Network Paging Console With microphone, wind shield, network cable

SX-NPMI

X-NPMI Configurable Network Paging Console

  • 4.3-inch color LCD touch screen
  • Intuitive and simple user interface
  • Detachable gooseneck microphone
  • Built-in monitor loudspeaker
  • Digital audio processing
  • Flush mount desktop installation available

X-NPMI Configurable Network Paging Console is a key module in X-618 Digital Public Address and
Voice Alarm System. It provides paging, monitoring, full duplex communication, touch screen operation and other configurable functions.

FEATURES

  • CONNECTIONS
    • X-618 system can connect with up to 20 X-NPMI via Ethernet. X-NPMI can be used as a node anywhere in the network. To reduce wiring cost, the devices can be connected into an existing network provided that there is sufficient bandwidth to reduce wiring cost.
  • AUDIO TRANSMISSION
    • The device comes with a detachable gooseneck microphone. Users can change different types of microphone for different real-time broadcasting requirements. The received audio signal will be digitalized to eliminate sound distortion during transmission.
    • The built-in speaker not only can be used for zone monitoring but also full-duplex intercom with other X-NPMI in the network.
    • X-NPMI supports fail-safe operation. Even when the connected X-DCS2000/EN fails, X-NPMI is still able to communicate with other X-NPMI and broadcast through other X-DCS2000/EN in the network.
  • TOUCH SCREEN
    • Users can operate directly on the innovative 4.3-inch color LCD touch screen without adding an extra key module unit. With the touch screen, users can supervise the system status, select broadcast zones, assign zone groups or other broadcast controls, including setting playlists, timing roadcastings etc. With the built-in configuration software, zones broadcast status or button functions can be configured easily.
  • SHORT-CUT OPERATION
    • X-NPMI has three short-cut buttons on the operation panel: microphone switch, all-zone emergency broadcast button can switch the system to emergency broadcast mode, where recorded evacuation message will be played and fire alarm will be activated without delay.

X-NPMI-R
X-NPMI-R

RACK MOUNT PANEL FOR X-NPMI

X-NPMI-R

X-NPMI Configurable Network Paging Console

  • 4.3-inch color LCD touch screen
  • Intuitive and simple user interface
  • Detachable gooseneck microphone
  • Built-in monitor loudspeaker
  • Digital audio processing
  • Flush mount desktop installation available

X-NPMI Configurable Network Paging Console is a key module in X-618 Digital Public Address and
Voice Alarm System. It provides paging, monitoring, full duplex communication, touch screen operation and other configurable functions.

FEATURES

  • CONNECTIONS
    • X-618 system can connect with up to 20 X-NPMI via Ethernet. X-NPMI can be used as a node anywhere in the network. To reduce wiring cost, the devices can be connected into an existing network provided that there is sufficient bandwidth to reduce wiring cost.
  • AUDIO TRANSMISSION
    • The device comes with a detachable gooseneck microphone. Users can change different types of microphone for different real-time broadcasting requirements. The received audio signal will be digitalized to eliminate sound distortion during transmission.
    • The built-in speaker not only can be used for zone monitoring but also full-duplex intercom with other X-NPMI in the network.
    • X-NPMI supports fail-safe operation. Even when the connected X-DCS2000/EN fails, X-NPMI is still able to communicate with other X-NPMI and broadcast through other X-DCS2000/EN in the network.
  • TOUCH SCREEN
    • Users can operate directly on the innovative 4.3-inch color LCD touch screen without adding an extra key module unit. With the touch screen, users can supervise the system status, select broadcast zones, assign zone groups or other broadcast controls, including setting playlists, timing roadcastings etc. With the built-in configuration software, zones broadcast status or button functions can be configured easily.
  • SHORT-CUT OPERATION
    • X-NPMI has three short-cut buttons on the operation panel: microphone switch, all-zone emergency broadcast button can switch the system to emergency broadcast mode, where recorded evacuation message will be played and fire alarm will be activated without delay.

X-NPMS
X-NPMS

Network Paging Console

X-NPMS

Configurable Network Paging Station

  • Easy touch screen operation with 7’’ TFT LCD screen and simple user interface.
  • Optional gooseneck microphone or PTT microphone.
  • Built-in loudspeaker for audio monitoring and intercommunication function.
  • Configurable keys for audio task delivery, zoning and grouping.

  • The X-NPMS connects to the X-618 system, transmitting audio and control signal through the Ethernet. It is used for live paging, audio task delivery , audio monitoring zones , and intercommunication.

    FEATURES

    • FUNCTIONS
      • Manual emergency broadcast
      • Normal broadcast control
      • Zoning and grouping broadcast
      • Monitoring function
      • Internal communication
      • Faults monitoring
      • Automatic record
      • Quick and simple broadcast
      • Recording audio in advance and broadcasting
      • Broadcasting the audio file of U-disk
      • Daily record
    • TOUCH SCREEN
      • Users can operate directly on the innovative 7-inch color LCD touch screen without adding an extra key module unit.With the touch screen, users can supervise the system status, select broadcast zones, assign zone groups or other broadcast controls, including setting playlists, timing broadcastings etc.
      • With the built-in configuration software, zones broadcast status or button functions can be configured easily.
    • CONNECTIONS
      • X-618 system can connect with up to 250 X-NPMS via Ethernet. X-NPMS can be used as a node anywhere in the network. To reduce wiring cost, the devices can be connected into an existing network provided that there is sufficient band width to reduce wiring cost.
    X-NRI/EN
    X-NRI/EN

    X-NRI/EN Network Resource Interface

    X-NRI/EN

  • 4 AUX balanced audio input for digitalization of the external analog audio source and routing to the network
  • Built-in 512MB Flash memory and 4G SD card as internal audio source
  • 4 Ethernet interfaces allow communication of multiple X-DCS2000/EN
  • 32 x dry contact control inputs with supervision and input faults can be monitored
  • 2 x RS-485 communication terminals for integration with Fire Panel via protocol
  • X-NRI/EN Network Resource Interface is a universal interface of X-618 for external control access and audio extension. It is suitable to the needs of central interfaces management required by middle-to-large applications.The device provides 4 external audio source interfaces and 1 built-in audio source.These audio sources are network audio source which can be shared in the Ethernet.

    FEATURES

    • BACKUP POWER SUPPLY
      • X-NRI/EN applies main power supply and 24 VDC backup power supply. Through software configuration, the fault of power supply can be detected. By default the device is running on main power. When the main power is disabled, it automatically relays to backup power supply and the main power indicator on X-NRI/EN front panel turns yellow at the same time.As long as the main power resume to normal, the power supply switch back to main power.
    • POWER SUPPLY PROTECTION
      • X-NRI/EN has main power protection. When internal short circuit or other forms of malfunction come across, the main power supply will be cut off for protection of the device.
    • SELF DETECTION
      • By self detection function, X-NRI/EN can detect faults include Main/Backup power supply, system malfunction, and communication fault and has respective indicators on the front panel. When there is a fault, the fault indicator turns yellow and siren goes off to warn the operators and the fault status will be logged.
    • EXTERNAL AUDIO SOURCE DELIVERY
      • X-NRI/EN has 4 RCA terminals for external audio source input. They can be configured by system software in terms of On/Off, the name of audio, multicast address and the type of interfaces, etc. During installation, the external audio source is required physically connection with the inputs and by using X-SMART software, X-NPMI/EN and X-DCS2000/EN to select the target zones and audio, the audio source can be delivered.
      • External audio sources can be connected to XNRI/EN directly such as CD or DVD. There are 4 balanced inputs for paging station connection and through dip switch on the right of rear panel, volume GAIN level can be adjusted and phantom power supply can be turned on/off.The power supply voltage of phantom power supply is DC 24V.
    • VOICE ALARM
      • X-NRI/EN provides 32 x dry contact inputs with monitoring for fire alarm integration. Through XSMART software, voice alarm zones of each XDCS2000/EN can be planned in accordance with fire alarm zones as well as the adjacent zones which required by international voice alarm standard. When fire alarm triggering the X-NRI/EN, it automatically communicate with the triggered X-DCS2000/EN and override the BGM broadcast by preserved voice message of emergency. When proceeding voice alarm in the zones on fire, X-DCS2000/EN can deliver the different evacuation message to preset adjacent zones.
    X-SP2000
    X-SP2000

    X-SMART System Resource Platform

    X-SP2000

    X-SMART X-618 Management Software

    The X-SMART System Management Software includes a server-side system resource platform and a client-side management system to perform centralized management of related devices through an Ethernet network. The software is used to monitor the system status, make announcements, play audio, and manage logs.

    There are two kinds of X-SMART software to meet the different requirements of projects of different sizes. One is for small and mediumsized project, and the other is for larger projects. These two kinds of software have the same operations. However, the number of X-DCS3000 (DSC) they control and the size of the devices connected are different

    The small and mediumsized project software can manage 20 DCSs at most, and play audio using 20 channels maximum through the network, among which 5 channels are for fire alarms and 15 for normal
    announcements.

    The large project software can manage up to 250 DCSs and play audio using 60 channels through the network, among which 10 channels are for fire alarms and 50 for public address.

    FEATURES

    • Flexible management of operation authorizations
    • Provide multiple-layer map view for the buildings
    • Records and show all events logs
    • Support system data backup
    • Fault detection reports the device ID, Type, and IP address
    • Monitor the status of all devices in the X-618 network
    • Supports multiple simultaneous announcements

    X-ND100

    Digital Noise Detector

    X-ND100

    X-ND100 (Digital Noise Detector) is used to detect ambient noise, automatically calculate the noise SPL, and transmit the SPL data to X-DCS3000. It is an important component to fulfill the function of automatic volume control. While broadcasting, the sound is mixed with ambient noise. In order to measure the noise SPL accurately, X-ND100 measures broadcast signal from speaker lines, comparing it with the broadcast signal from the microphone to get the actual noise data.

    INSTALLATION NOTES

    • Installation
      • Builders can conveniently install the noise detector into a hole with diameter of 160mm in the ceiling, and secure it with the spring clamps on both sides of the shell. Thickness of the ceiling is 5~25mm.
    • Wiring
      • There are two terminals inside the noise detector. One is used to connect the control line for communication and power supply, and another is used to connect the speaker line. The polarity of wires shall conform to the marks beside the terminals. Generally, 0.75mm2 twisted wires are recommended. If the distance from the noise detector to controller exceeds 1000m, please use 1mm2 twisted wires.

    FEATURES

    • Connect to the X-DCS3000 by a pair of cables, to the communication and power terminals.
    • Max. 5 noise detectors for each channel.
    • Fire-proof ABS shell.
    • Collects broadcast signals and noise signals.
    • Max. transmission distance is 1000m.
    • Flush-mounting in ceiling.
    • Ideal for indoor installation.
    X-DA4125EN
    X-DA4125EN

    X-DA4125EN High Efficiency Power Amplifier 4×125W with 24 VDC backup power supply

    X-DA4125EN

    X-DA4125EN High Efficiency Power Amplifier with 24 VDC Backup Power Supply

  • Four channels 125W efficiency Class-D amplifier
  • Effective ventilation using forced air cooling fan
  • Automatic protection
  • Fault detection
  • CE complied
  • With 24 VDC backup power supply
  • X-DA4125EN is the Class-D amplifier and it is lighter, more stable, and high efficiency. The audio transmission is completely digitalized which makes it free from interference and easy to be controlled. It also has 24 VDC backup power supply conforming to international voice alarm standard which is the perfect choice for safety required applications.

    FEATURES

    • INPUT/OUTPUT
      • X-DA4125EN supports both balanced and unbalanced audio inputs.To receive unbalanced audio inputs, simply connect the ground port with the negative input port to the rear panel.
      • X-DA4125EN can receive audio signal from XDCS2000/EN via Ethernet through the RJ45 standard port.
    • FAULT DETECTION
      • X-DA4125EN can self-protect from overheat, over current, over voltage and under voltage. For example, when the internal temperature reaches its critical limit, the overheat protection circuit will shut down the power amplification module and activate the protection indicator light on the front panel.
      • X-DA4125EN can detect power supply errors automatically during operation.The built-in fuse will provide over current protection to the main power supply.
      • When a shout circuit is detected in the main power supply circuit, the power will be automatically shut down.The backup power supply will then be enabled to replace the main one.
      • When a fault, self-protection or self-testing happens, its audio input fault port on the rear panel will short circuit and a fault signal will then be sent to the control unit in the network.
    • SAFETY
      • The device adopts lightweight design. The front panel is made of UL94V-0 fire proof ABS material, protecting the machine under extreme conditions. A cooling fan is equipped for heat exhaustion so that the machine can maintain high working efficiency. The amplifier can work without main power in emergency.
    • VOLUME CONTROL
      • When HN-D32N Noise Detector is installed, X-DA4125EN can adjust volume according to the ambient noise automatically to ensure high sound intelligibility.
    • INDICATORS
      • with 24 VDC Backup Power Supply
      • Power light
      • AC fault light
      • DC fault light
      • Signal light (for each channel)
      • Clip light (for each channel)
      • Protection light (for each channel)