Search for:

586115

Doormaster-Smart-PAL-Telephone interface
586115

DOORMASTER-SMART-PAL-Telephone interface is used for recording the announcements via similar
telephone system in VARIODYN D1 voice alarm system. Up to 4 different call circuits or areas can be
addressed using the telephone system. For this purpose 1+ 4 control contacts are available for switching on
and/or zone selection.

The connection of telephone interface to VARIODYN D1 takes place via control inputs and audio input of
UIM Part. No. 583331.21. 12 V operating voltage can be generated from 24 V emergency power supply
with voltage converter Part No. 781336 that is available in the voice alarm system. The voltage converter
can be mounted in housing Part No. 788603 on the C-rail in rack.

The programming takes place with MFV post dial, so that the device can also be used from distance.

FEATURES
  • Operating voltage : 12 V DC 
  • Current consumption @ 12 V DC : approx. 100 mA 
  • Contact load relay :  24 V DC/0,5 A (relay 1/2)
  • Ambient temperature :   -5 °C … 45 °C 
  • Mounting :  mounting rail 
  • Dimensions :    W: 52 mm H: 89 mm D: 57 mm

586116

Power supply for telephone interface
586116

Power supply for telephone interface part no. 586115

FEATURES
  • Rated voltage : 127 / 230 V AC
  • Output voltage : 13 V AC
  • Output current : max. 0.6 A

586103

Table call station with DIGIM4

586104

Flush-mount box f. DIGIST09

586102

Table call station with DIGIM1

584971

Contactor 3×25 A
584971

In combination with the neutral conductor monitoring module (Part No. 584970) this contactor enables the safe and immediate all-pole interruption of the power supply in the event of:

  • undervoltage
  • phase failure
  • asymmetry, including for reverse voltage
  • neutral conductor missing in the system
  • neutral conductor break in the device supply cable
  • neutral conductor mixed up with phase

584970

Under Voltage and neutral supervision module
584970

The neutral conductor monitoring module (Part No. 584970) should be used to protect against a break in the neutral conductor occurring. This module is connected upstream with the MSU contactor (Part No. 584971) and enables the safe and immediate all-pole interruption of the power supply in the event of:

  • undervoltage
  • phase failure
  • asymmetry, including for reverse voltage
  • neutral conductor missing in the system
  • neutral conductor break in the device supply cable
  • neutral conductor mixed up with phase.
  • Single phase connection possible

FEATURES
  • Compliant to IEC/EN 60 255, DIN VDE 0435-303
  • Single phase connection possible
  • Fixed setting value
  • Closed circuit operation principle
  • LED indicator
  • With safe disconnection compliant to IEC/EN 61 140, IEC/EN 60 947-1 between the Measuring Circuit and the contacts
  • Independent of phase sequence
  • 2 changeover contacts

584962

Housing f. two DCSF1 or DCSF12

584961

Housing f. one DCSF1 or DCSF12