Search for:
L-PWP40B

L-PWP40B : HONEYWELL ตู้ลำโพงขนาด 40 W, รองรับความถี่ 100 Hz -20 kHz, ผลิตจากวัสดุ ABS, สามารถใช้ไดภายในอาคาร, สีดำ


FEATURES

  • Max power: 60 W
  • Rated power: 40 W
  • Power taps@100 V: 40 W / 20 W / 10 W
  • Power taps@70 V: 20 W / 10 W / 5 W
  • Frequency response (-10 dB): 100 Hz – 20 kHz
  • SPL at 40 W/ 1W (130 Hz-20 kHz, 1m): 99 dB/ 84 dB
  • Dispersion angle (1 kHz / -6 dB): 160 °
  • Rated input voltage: 100 V/ 70 V/ 8 Ω
  • Rated impedance: 250 Ω/ 500 Ω/ 1 kΩ
  • Connector: Binding post terminals
  • Dimensions (W × H × D): 172 × 302 × 165 mm
  • Diameter of speaker: 5.25″ woofer, 1″ tweeter
  • Weight: 3.2 kg
  • Color: Charcoal (RAL 7021)

TECHNICAL SPECIFICATIONS

580243 Honeywell Power Four-Channel Amplifier 4XD250B

580243: Honeywell Power Four-Channel Amplifier 4XD250B ระบบเสียงประกาศสาธารณะและระบบเตือนภัยด้วยเสียง


Four-channel amplifier with integrated battery recharging system for the emergency power supply to the
VARIODYN D1 Comprio. The 4XD250B features 4 independent amplifier channels, each with 250 W, in
class D direct drive technology. Due to the fact that all amplifier channels are completely independent from
each other, it is possible to use one channel for back up. This could be for the other 3 channels or
alternatively for other amplifier channels of other amplifiers with the same or lower output power (only
4XDxxxB and 4XDxxxW models). The amplifier can be used in combination with the VARIODYN D1
Comprio as well as with a DOM. It is also possible to use the amplifier also with a separate PSU, the
internal PSU must be switched of then. In this case the internal battery charger must be disabled.

FEATURES

  • EN 54-4 and EN 54-16 certified
  • Compliant with EN 60849 and EN 50849
  • Class D technology, efficiency> = 80 %
  • 4 independent amplifier channels
  • One of four amplifier channels can be used as general back up channel
  • Two Height Unit (2 HU)
  • Ideal for use with the VARIODYN D1 Comprio
  • Self-monitoring and self-test by microcontroller
  • Protected against overload, short circuit and overheating
  • Smooth and fast step-down in 1dB steps in the event of overdrive or over load
  • 24 V DC PSU for back up mains power
  • Integrated battery charger according to EN 54-4 for charging batteries up to a capacity of 65 Ah (2 x 12V / 105 Ah) for emergency power supply of the amplifier and one Comprio or DOM
  • Temperature controlled variable speed fans

SPECIFICATION

586115
Doormaster-Smart-PAL-Telephone interface
586115

DOORMASTER-SMART-PAL-Telephone interface is used for recording the announcements via similar
telephone system in VARIODYN D1 voice alarm system. Up to 4 different call circuits or areas can be
addressed using the telephone system. For this purpose 1+ 4 control contacts are available for switching on
and/or zone selection.

The connection of telephone interface to VARIODYN D1 takes place via control inputs and audio input of
UIM Part. No. 583331.21. 12 V operating voltage can be generated from 24 V emergency power supply
with voltage converter Part No. 781336 that is available in the voice alarm system. The voltage converter
can be mounted in housing Part No. 788603 on the C-rail in rack.

The programming takes place with MFV post dial, so that the device can also be used from distance.

FEATURES
  • Operating voltage : 12 V DC 
  • Current consumption @ 12 V DC : approx. 100 mA 
  • Contact load relay :  24 V DC/0,5 A (relay 1/2)
  • Ambient temperature :   -5 °C … 45 °C 
  • Mounting :  mounting rail 
  • Dimensions :    W: 52 mm H: 89 mm D: 57 mm

586116
Power supply for telephone interface
586116

Power supply for telephone interface part no. 586115

FEATURES
  • Rated voltage : 127 / 230 V AC
  • Output voltage : 13 V AC
  • Output current : max. 0.6 A

584971
Contactor 3×25 A
584971

In combination with the neutral conductor monitoring module (Part No. 584970) this contactor enables the safe and immediate all-pole interruption of the power supply in the event of:

  • undervoltage
  • phase failure
  • asymmetry, including for reverse voltage
  • neutral conductor missing in the system
  • neutral conductor break in the device supply cable
  • neutral conductor mixed up with phase

584970
Under Voltage and neutral supervision module
584970

The neutral conductor monitoring module (Part No. 584970) should be used to protect against a break in the neutral conductor occurring. This module is connected upstream with the MSU contactor (Part No. 584971) and enables the safe and immediate all-pole interruption of the power supply in the event of:

  • undervoltage
  • phase failure
  • asymmetry, including for reverse voltage
  • neutral conductor missing in the system
  • neutral conductor break in the device supply cable
  • neutral conductor mixed up with phase.
  • Single phase connection possible

FEATURES
  • Compliant to IEC/EN 60 255, DIN VDE 0435-303
  • Single phase connection possible
  • Fixed setting value
  • Closed circuit operation principle
  • LED indicator
  • With safe disconnection compliant to IEC/EN 61 140, IEC/EN 60 947-1 between the Measuring Circuit and the contacts
  • Independent of phase sequence
  • 2 changeover contacts