MHR/1

Mini-horn/Red

Honeywell’s MHR/1 min-horn features a red housing and universal fire symbol to meet virtually any application requirement. A mounting plate allows the device to be compatible with a wide range of backbox sizes. Its settings are done using easy-to-set rotary switches on the back of the device while synchronization is achieved without the use of additional modules.

SYS/HS/C

Ceiling-mount Strobe

Honeywell’s SYS/ST/C strobe features a red housing and universal fire symbol to meet virtually any application requirement. A mounting plate allows the device to be compatible with a wide range of backbox sizes. Its settings are done using easy-to-set rotary switches on the back of the device while synchronisation is achieved without the use of additional modules. When powered with a filtered DC source, it is capable of self synchronization for 30 minutes per NFPA72.

SYS/ST/C

Ceiling-mount Strobe

Honeywell’s SYS/ST/C strobe features a red housing and universal fire symbol to meet virtually any application requirement. A mounting plate allows the device to be compatible with a wide range of backbox sizes. Its settings are done using easy-to-set rotary switches on the back of the device while synchronisation is achieved without the use of additional modules. When powered with a filtered DC source, it is capable of self synchronization for 30 minutes per NFPA72.

SYS/HS

Standard: UL

  • It is possible to set the display light to high or low, the volume setting for 3 levels of continuous and temporary.
  • Luxurious design with high aesthetics, compact and easy to install.
  • Automatically synchronize alarm flash light for 30 minutes.
  • Flash mode after 1 second

FEATURES

  • Operating temperature: 0-49 degrees Celsius
  • Humidity: 10-93% RH, No dew condensation.
  • Operating voltage: 16-33 VDC (normally at 24V)
  • Sound intensity: ≥82dBA.

SYS/ST

Horn-Strobe Light Red

Honeywell’s SYS/ST strobe features a red housing and universal fire symbol to meet virtually any application requirement. A mounting plate allows the device to be compatible with a wide range of backbox sizes. Its settings are done using easy-to-set rotary switches on the back of the device while synchronization is achieved without the use of additional modules. When powered with a filtered DC source, it is capable of self synchronization for 30 minutes per NFPA72.

S300PTU

The S300PTU Programming and Test Tool is a menu driven device, designed for communication with System Sensor Series 300 detectors, permitting access to various functions and logs within the detectors.

Communication is achieved via an LED and opto-diode built in to the S300PTU, for close range communication. This allows direct communication via the detector LED indicator.

S300DAPU

Honeywell Detector Address Programmer Unit

  • Operating Voltage: 12 VDC, 1A
  • Fuse Rating: 1A
  • Display: 16 x 2 LCD display
  • Push Buttons: 12 mm Momentary Push Button Switch
  • Mechanical dimensions: 214 x 138 x 89mm
  • Weight: 1.26 Kg.

HML/RHSE

HML/RHSE : ตัวตรวจจับความร้อนหรือสโมคดีเทคเตอร์ ยี่ห้อ Morley สามารถตั้งค่าแอดเดรส ได้ใช้คู่กับ ตู้ไฟอลาม Morley-Lite


The HML/RHSE thermal detector forms part of the HML Series range of addressable detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing detector technology.

The HML/RHSE thermal detector incorporates an Application Specific Integrated Circuit (ASIC). Combined with the latest in thermal element technology the detector provides efficient and accurate detection of fires, especially in environments such as bars or kitchens where smoke detectors are inappropriate due to the high level of airborne contamination.

The HML/RHSE and other detectors in the HML Series range are backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations. The HML/RHSE detector incorporates a bi-colour LED indicator. The integral LED changes colour according to the detector’s status – Green = Normal, Red = Alarm. This benefits the user by providing clear, instant visual indication of the detector’s condition. The Green LED can be programmed for
blink/no blink operation.

The remote hand-held programming unit can also be used in conjunction with the HML Series range of detectors to gain access to other advanced features. The features available include: read/write last maintenance date, read value of thermal element and perform an alarm test.

Each unit can be given a unique address that will be displayed on the Honeywell Morley Lite Panel LCD whenever the detector is in alarm.

All the features via the hand-held programming unit are achieved effectively and effortlessly without the need to remove the detector or having to gain direct physical access (other than by the use of ‘No Climb Products’ or similar servicing tool), saving valuable commissioning/maintenance time.

They provide the end user with the confidence to know that his system is being regularly serviced and that it is operating at its optimum level, with minimum disruption to his own business activities.

  • Low profile design
  • Low current draw
  • Backward compatible with Series 100 detector range of bases
  • Wide operating voltage 8 to 30VDC
  • Bi-colour LED detector status indicator
  • Programmable sensitivity
  • Addressable feature
  • Advanced maintenance features via remote hand-held test unit
  • Range of detector bases available

HML/PSE

HML/PSE: HONEYWELL MORLEY อุปกรณ์ตรวจจับความร้อนหรือสโมคดีเทคเตอร์ สามารถตั้งค่าแอดเดรสได้ ใช้ร่วมกับตู้ไฟอลาม Morley-Lite


The HML/PSE photoelectric smoke detector forms part of the Honeywell Morley Lite range of addressable detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing detector technology.

The HML/PSE photoelectric detector incorporates an Application Specific Integrated Circuit (ASIC). Combined with the latest state of the art optical chamber the detector provides efficient and
accurate detection of fires with a high level of resilience to non-fire environmental influences.

The HML/PSE detector is backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations.

The HML/PSE detector incorporates a bi-colour LED indicator. The integral LED changes colour according to the detector’s status – Green = Normal, Red = Alarm. This benefits the user by providing clear, instant visual indication of the detector’s condition. The Green LED can be programmed for blink/no blink operation.

‘Drift compensation’ algorithms are one of the key features of the HML/PSE detector. These algorithms ensure a consistent alarm sensitivity threshold for periods between service intervals. This provides the user with both a reduction in the frequency of nuisance alarms and maintenance savings by extending the
period before cleaning of the detector chamber is required.

The sensitivity of a smoke detector is critical to its overall performance, this is reflected in both its ability to detect real fire conditions and its resilience to non-fire stimuli. The HML/PSE’s performance can be optimised for it’s application by selecting from one of three preset alarm thresholds – Low, Medium and High, offering greater stability and optimum performance within the environment in which it has been installed. The selection is easily achieved through the use of a remote hand-held tool.

The remote hand-held programming unit can also be used to gain access to other advanced features. The features available include: read/write last maintenance date, read chamber contamination level, read value of thermal element and perform an alarm test.

  • Low profile design
  • Low current draw
  • Backward compatible with Series 100 detector range of bases
  • Wide operating voltage 8 to 30VDC
  • Bi-colour LED detector status indicator
  • Automatic drift compensation
  • Programmable sensitivity
  • Addressable feature
  • Advanced maintenance features via remote hand-held test unit
  • Range of detector bases available

HML/PTSE

The HML/PTSE photoelectric smoke/thermal detector forms part of the HML Series of Addressable detectors. This range of detectors has been produced using the latest in manufacturing and design
techniques, pushing out the boundaries of existing detector technology.

The HML/PTSE photoelectric smoke/thermal detector incorporates an optical chamber and a thermal element, which in turn are continually monitored by an on board processor by using algorithms
developed specifically for the unit. An alarm signal is only enabled in the detector once the processor is satisfied that an incipient fire has been detected. By using a combination of inputs, the incidence of
nuisance alarms is reduced while at the same time, the response time to an actual fire is also improved.

The HML/PTSE and other detectors in the HML Series range are backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations. The HML/PTSE detector incorporates a bi-colour LED indicator. The integral LED changes colour according to the detector’s status – Green = Normal, Red = Alarm. This benefits the user by providing clear, instant visual indication of the detector’s condition. The Green LED can be programmed for
blink/no blink operation.

Drift compensation’ algorithms are one of the key features of the HML/PTSE detector. These algorithms ensure a consistent alarm sensitivity threshold for periods between service intervals. This provides the user with both a reduction in the frequency of nuisance alarms and maintenance savings by extending the period
before cleaning of the detector chamber is required.

The sensitivity of a smoke detector is critical to its overall performance, this is reflected in both its ability to detect real fire conditions and its resilience to non-fire stimuli. The HML/PTSE’s performance can be optimised for it’s application by selecting from one of three preset alarm thresholds – Low, Medium and High, offering greater stability and optimum performance within the environment in which it has been installed. The selection is easily achieved through the use of a remote hand-held tool.

The remote hand-held programming unit can also be used in conjunction with the HML Series range of detectors to gain access to other advanced features. The features available include: read/write last maintenance date, read chamber contamination level, read value of thermal element and perform an alarm test.

  • Low profile design
  • Low current draw
  • Backward compatible with Series 100 detector range of bases
  • Wide operating voltage 8 to 30VDC
  • Bi-colour LED detector status indicator
  • Automatic drift compensation
  • Programmable sensitivity
  • Addressable feature
  • Advanced maintenance features via remote hand-held test unit