Search for:

MI/RHSE/S2I/IV

Rate of Rise Thermal Sensor with Isolator
MI/RHSE/S2I/IV

S200A incorporates major hardware and software technology driven developments. A completely new optical chamber design is proven in extensive testing to be more efficient, less liable to is proven in extensive testing to be more efficient, less liable to false alarm due to dust and insects and less susceptible to fault in high air velocities or back pressure. Extensive hydrodynamic modelling has confirmed the greater efficiency of the new chamber and housing shape combination. Large-scale integration of the all-new electronics, through the fully automated surface mount PCB assembly, coupled with in-line testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers
i.mproved quality and reliability

All S200A detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs, and are mechanically and electrically backwards c. ompatible with existing devices.

FEATURES
  • Available with or without short circuit isolation
  • Isolator per device allowsfaster, more precise fault finding
  • Rotary decade address switches
  • Ivory colour to harmonise with the modern built environment
  • 100% mechanical and electrical backwards compatibility
  • New base design to complement the detector and ease installation and wiring

MI/RHSE/S2/IV

Rate of Rise Thermal Sensor
MI/RHSE/S2/IV

S200A incorporates major hardware and software technology driven developments. A completely new optical chamber design is proven in extensive testing to be more efficient, less liable to is proven in extensive testing to be more efficient, less liable to false alarm due to dust and insects and less susceptible to fault in high air velocities or back pressure. Extensive hydrodynamic modelling has confirmed the greater efficiency of the new chamber and housing shape combination. Large-scale integration of the all-new electronics, through the fully automated surface mount PCB assembly, coupled with in-line testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers
i.mproved quality and reliability

All S200A detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs, and are mechanically and electrically backwards c. ompatible with existing devices.

FEATURES
  • Available with or without short circuit isolation
  • Isolator per device allowsfaster, more precise fault finding
  • Rotary decade address switches
  • Ivory colour to harmonise with the modern built environment
  • 100% mechanical and electrical backwards compatibility
  • New base design to complement the detector and ease installation and wiring

MI/PSE/S2I/IV

Smoke Sensor with Isolator
MI/PSE/S2I/IV

S200A incorporates major hardware and software technology driven developments. A completely new optical chamber design is proven in extensive testing to be more efficient, less liable to is proven in extensive testing to be more efficient, less liable to false alarm due to dust and insects and less susceptible to fault in high air velocities or back pressure. Extensive hydrodynamic modelling has confirmed the greater efficiency of the new chamber and housing shape combination. Large-scale integration of the all-new electronics, through the fully automated surface mount PCB assembly, coupled with in-line testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers
i.mproved quality and reliability

All S200A detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs, and are mechanically and electrically backwards c. ompatible with existing devices.

FEATURES
  • Available with or without short circuit isolation
  • Isolator per device allowsfaster, more precise fault finding
  • Rotary decade address switches
  • Ivory colour to harmonise with the modern built environment
  • 100% mechanical and electrical backwards compatibility
  • New base design to complement the detector and ease installation and wiring

MI/PSE/S2/IV

Smoke Sensor
MI/PSE/S2/IV

S200A incorporates major hardware and software technology driven developments. A completely new optical chamber design is proven in extensive testing to be more efficient, less liable to is proven in extensive testing to be more efficient, less liable to false alarm due to dust and insects and less susceptible to fault in high air velocities or back pressure. Extensive hydrodynamic modelling has confirmed the greater efficiency of the new chamber and housing shape combination. Large-scale integration of the all-new electronics, through the fully automated surface mount PCB assembly, coupled with in-line testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers
i.mproved quality and reliability

All S200A detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs, and are mechanically and electrically backwards c. ompatible with existing devices.

FEATURES
  • Available with or without short circuit isolation
  • Isolator per device allowsfaster, more precise fault finding
  • Rotary decade address switches
  • Ivory colour to harmonise with the modern built environment
  • 100% mechanical and electrical backwards compatibility
  • New base design to complement the detector and ease installation and wiring

MI/FHSE/S2/IV

58°C Thermal Sensor
MI/FHSE/S2/IV

S200A incorporates major hardware and software technology driven developments. A completely new optical chamber design is proven in extensive testing to be more efficient, less liable to is proven in extensive testing to be more efficient, less liable to false alarm due to dust and insects and less susceptible to fault in high air velocities or back pressure. Extensive hydrodynamic modelling has confirmed the greater efficiency of the new chamber and housing shape combination. Large-scale integration of the all-new electronics, through the fully automated surface mount PCB assembly, coupled with in-line testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers
i.mproved quality and reliability

All S200A detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs, and are mechanically and electrically backwards c. ompatible with existing devices.

FEATURES
  • Available with or without short circuit isolation
  • Isolator per device allowsfaster, more precise fault finding
  • Rotary decade address switches
  • Ivory colour to harmonise with the modern built environment
  • 100% mechanical and electrical backwards compatibility
  • New base design to complement the detector and ease installation and wiring

HM/RHSE

RATE OF RISE HEAT DETECTOR
HM/RHSE

Honeywell Morley-IAS HM Series detectors incorporate modern hardware and software technology driven developments. An advanced optical chamber design is proven in extensive testing to be more efficient, less
liable to false alarm from dust and insects and less susceptible to fault in high air velocities or back pressure.

Extensive hydrodynamic modelling has confirmed the greater efficiency of the chamber and housing shape combination. Large-scale integration of the electronics, through the fully automated surface mount PCB
assembly, coupled with in-line testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers improved quality and reliability.

All detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs.

Product Range
The family consists of four detection devices: two heat detectors (58° and a rate of rise), an optical smoke, and a photo-thermal multi-sensor. The detector base makes the installation process easy and quick.
These sensors are designed for open area protection and must only be connected to fire alarm panels that use a compatible proprietary communication protocol for monitoring and control (DXc panels R7, 8, 9).

Specifications: Thermal Detector
The intelligent thermal sensors are point type fire sensors that use an accurate thermistor sensing circuit to provide early warning of developing fires, together with addressable communication with the fire alarm panel.

The HM/RHSE thermal detector provides fixed 58°C and rate-of-rise (10°C/minute) temperature sensing (Class A1R).

FEATURES
  • Rotary decade address switches
  • Aesthetic design to harmonise with the modern built environment
  • Base complements the detector and is easy to installe and wire
  • Genuine and fast response
  • Advanced protocol and smoothing filter to suppress false alarm
  • Easy to maintain (washable filter)
  • Analog addressable communication
  • Enhanced smoke chamber design to reduce false alarms by dust or contamination
  • Dual integrated LED for 360° visibility
  • LPCB approved
  • Conforms to EN54-7/ EN54-5 and EN54-29
  • Environment friendly – meets RoHS legislative requirements
  • For DXc fire alarm panels R7, 8, 9

HM/PTSE

HM/PTSE

OPTICAL-THERMAL SMOKE DETECTOR
HM/PTSE

Honeywell Morley-IAS HM Series detectors incorporate modern hardware and software technology driven developments. An advanced optical chamber design is proven in extensive testing to be more efficient, less
liable to false alarm from dust and insects and less susceptible to fault in high air velocities or back pressure.

Extensive hydrodynamic modelling has confirmed the greater efficiency of the chamber and housing shape combination. Large-scale integration of the electronics, through the fully automated surface mount PCB
assembly, coupled with in-line testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers improved quality and reliability.

All detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs.

Product Range
The family consists of four detection devices: two heat detectors (58° and a rate of rise), an optical smoke, and a photo-thermal multi-sensor. The detector base makes the installation process easy and quick.
These sensors are designed for open area protection and must only be connected to fire alarm panels that use a compatible proprietary communication protocol for monitoring and control (DXc panels R7, 8, 9).

Specifications: Optical Smoke / Thermal Multi-Criteria Fire Detectors
The optical-thermal sensor uses thermal assistance to the core photoelectric smoke detector to give enhanced false alarm immunity and faster response to a wide range of incipient fires. The plug-in unit combines two separate sensing elements that are managed by embedded software to act as a single unit.

The optical-thermal detector conforms to EN54-7, a 58°C fixed temperature and rate of rise thermal assistance conforming to EN54-5. The thermal detection function combines thermistor technology with a software corrected linear temperature response. In areas where the normal daytime activities may potentially create unwanted alarms, the detector can be programmed to operate in a “heat only” mode, automatically reverting to full photo-thermal operation during unoccupied periods.

The sensing elements of the HM-PTSE optical-thermal detector are adjustable so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detector has two integral red LEDs that provide 360° local visual indication of the device status.

FEATURES
  • Rotary decade address switches
  • Aesthetic design to harmonise with the modern built environment
  • Base complements the detector and is easy to installe and wire
  • Genuine and fast response
  • Advanced protocol and smoothing filter to suppress false alarm
  • Easy to maintain (washable filter)
  • Analog addressable communication
  • Enhanced smoke chamber design to reduce false alarms by dust or contamination
  • Dual integrated LED for 360° visibility
  • LPCB approved
  • Conforms to EN54-7/ EN54-5 and EN54-29
  • Environment friendly – meets RoHS legislative requirements
  • For DXc fire alarm panels R7, 8, 9

HM/PSE

OPTICAL SMOKE DETECTOR
HM/PSE

Honeywell Morley-IAS HM Series detectors incorporate modern hardware and software technology driven developments. An advanced optical chamber design is proven in extensive testing to be more efficient, less
liable to false alarm from dust and insects and less susceptible to fault in high air velocities or back pressure.

Extensive hydrodynamic modelling has confirmed the greater efficiency of the chamber and housing shape combination. Large-scale integration of the electronics, through the fully automated surface mount PCB
assembly, coupled with in-line testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers improved quality and reliability.

All detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs.

Product Range
The family consists of four detection devices: two heat detectors (58° and a rate of rise), an optical smoke, and a photo-thermal multi-sensor. The detector base makes the installation process easy and quick.
These sensors are designed for open area protection and must only be connected to fire alarm panels that use a compatible proprietary communication protocol for monitoring and control (DXc panels R7, 8, 9).

Specifications: Optical Smoke Detector
The photoelectric smoke sensor delivers high responsiveness, reduced sensitivity to dust and false alarms resulting from ingress of insect and other debris. The plug-in unit uses sophisticated processing circuitry that incorporates smoothing filters to help eliminate transient environmental noise conditions that can be the cause of unwanted alarms. The devices are managed by embedded software running complex algorithms that further improve resilience to false alarms and improve detection speed.

The HM/PSE optical smoke detector has two integral red LEDs that provide 360° local visual indication of the device status.

FEATURES
  • Rotary decade address switches
  • Aesthetic design to harmonise with the modern built environment
  • Base complements the detector and is easy to installe and wire
  • Genuine and fast response
  • Advanced protocol and smoothing filter to suppress false alarm
  • Easy to maintain (washable filter)
  • Analog addressable communication
  • Enhanced smoke chamber design to reduce false alarms by dust or contamination
  • Dual integrated LED for 360° visibility
  • LPCB approved
  • Conforms to EN54-7/ EN54-5 and EN54-29
  • Environment friendly – meets RoHS legislative requirements
  • For DXc fire alarm panels R7, 8, 9

HM/FHSE

PFIXED TEMPERATURE HEAT DETECTOR
HM/FHSE

Honeywell Morley-IAS HM Series detectors incorporate modern hardware and software technology driven developments. An advanced optical chamber design is proven in extensive testing to be more efficient, less
liable to false alarm from dust and insects and less susceptible to fault in high air velocities or back pressure.

Extensive hydrodynamic modelling has confirmed the greater efficiency of the chamber and housing shape combination. Large-scale integration of the electronics, through the fully automated surface mount PCB
assembly, coupled with in-line testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers improved quality and reliability.

All detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs.

Product Range
The family consists of four detection devices: two heat detectors (58° and a rate of rise), an optical smoke, and a photo-thermal multi-sensor. The detector base makes the installation process easy and quick.
These sensors are designed for open area protection and must only be connected to fire alarm panels that use a compatible proprietary communication protocol for monitoring and control (DXc panels R7, 8, 9).

Specifications: Thermal Detector
The intelligent thermal sensors are point type fire sensors that use an accurate thermistor sensing circuit to provide early warning of developing fires, together with addressable communication with the fire alarm panel.

The HM/FHSE thermal detector provides fixed 58°C temperature sensing (Class A1S). The detectors have two integral red LEDs that provide 360° local visual indication of the device status.

FEATURES
  • Rotary decade address switches
  • Aesthetic design to harmonise with the modern built environment
  • Base complements the detector and is easy to installe and wire
  • Genuine and fast response
  • Advanced protocol and smoothing filter to suppress false alarm
  • Easy to maintain (washable filter)
  • Analog addressable communication
  • Enhanced smoke chamber design to reduce false alarms by dust or contamination
  • Dual integrated LED for 360° visibility
  • LPCB approved
  • Conforms to EN54-7/ EN54-5 and EN54-29
  • Environment friendly – meets RoHS legislative requirements
  • For DXc fire alarm panels R7, 8, 9

TGP-DXC

TGP-DXC

GRAPHIC SOFT LICENSE FOR Dxc
TGP-DXC

Honeywell TGP-DXC. TGP-DXC DXC central additional expansion license Licencia adicional de programa de graficos para centrales dxc. permite la conexion de una central.

FEATURES
  • Programm expansion license for graphic management of DXC TGP-DXC centrals.
  • For the control of an additional central within the TG-XXX base program or main control post.
  • It allows you to reset, silence sirens, cancel / enable points and zones.
  • Know the location and status of the devices in the different plans of an installation.
  • Import the description of the devices of the central and create a maintenance file with the analog value of the sensors.
  • For the management of additional exchanges, as many expansion software licenses as control panels TGP-DXC are required.